W-10KL 10 kVA UPS Online Frekuensi Rendah dengan Transformator Isolasi, Input/Output 3-Fasa 380 V
| Capcity: | 10KVA/8KW | Input: | 3 x 380VAC/400VAC (3Ph + N) |
| Frequency: | 50Hz&60Hz | Nominal Battery Voltage: | 384 VDC (Based on 32pcs batteries) |
| Precision: | Stationary: ±1% Transitory: ±5% (load variations 100-0-100%) | Waveform: | Pure Sinewave |
| Output: | 3 x 380VAC/400VAC (3Ph + N) | Transfer Time: | Zero |
| Current Limit: | High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit | Charging Current: | Default 10A; Maximum 40A; 5A@ full load |
| Capacity: | 10 kVA / 8 kW | Topology: | Low frequency, online double-conversion |
| Input / Output: | 380 / 400 / 415 V AC, 3-phase | Input Voltage Range: | 285–485 V AC (Ph-Ph) |
| Input frequency range: | 50 / 60 Hz, ±10% | Isolation transformer: | Built-in output isolation transformer |
| Transfer Time: | 0 ms (mains to battery) | Battery system: | 384 VDC nominal, 32 × 12 V batteries (29–32 adjustable) |
| High Light: | UPS Frekuensi Rendah 10KVA/8KW,Catu Daya Tak Terputus Sinewave Murni,UPS Input Ganda Waktu Transfer Nol |
||
W-10KL menyediakan output terproteksi hingga 8 kW untuk panel kontrol tiga fase, bangku uji listrik, dan peralatan bantu industri. Desain konversi ganda online-nya mencakup transformator isolasi output bawaan dan transfer daya-ke-baterai 0 ms. Input utama dan bypass terpisah serta bank baterai eksternal 384 VDC memungkinkan sistem cadangan dikonfigurasi untuk lokasi.
Mencocokkan beban tiga fase yang ringkas
Batas output 8 kW sama pentingnya dengan peringkat 10 kVA. Cantumkan peralatan kontrol aktual, motor bantu, dan instrumen uji sebelum memutuskan sirkuit mana yang harus tetap dialiri daya cadangan.
Rentang input penyearah adalah 285–485 V AC line-to-line; bypass memiliki jendela yang lebih sempit sendiri yaitu 304–456 V AC. Ini adalah jalur operasi yang berbeda dan harus dipertimbangkan secara terpisah saat meninjau catatan tegangan lokasi.
Di mana W-10KL cocok
Jangan mengukur unit ini dari pelat nama seluruh mesin jika hanya bagian kontrolnya yang memerlukan cadangan. Pisahkan sirkuit penting dari motor atau pemanas yang tidak harus tetap dialiri daya.
Konfigurasi baterai
W-10KL menggunakan bank baterai VRLA eksternal. Sistem nominalnya adalah 384 VDC dengan baterai 32 × 12 V. Jumlah baterai dapat dikonfigurasi dari 29 hingga 32 baterai, sesuai dengan 348 / 360 / 372 / 384 VDC.
Tegangan pengisian daya dapat disesuaikan dari 395–435 VDC. Produsen mencantumkan nilai arus pengisian daya hingga 40 A dan 5 A pada beban UPS penuh. Arus pengisian daya yang tersedia bergantung pada beban UPS dan konfigurasi pengisi daya yang disediakan. Kapasitas Ah baterai harus dipilih berdasarkan beban yang terhubung dan waktu cadangan yang diperlukan.
Spesifikasi teknis
Lihat spesifikasi teknis lengkap
Input utama
| Tegangan input nominal | 380 / 400 / 415 V AC |
|---|---|
| Rentang tegangan input | 165–280 V AC (Ph-N); 285–485 V AC (Ph-Ph) |
| Fase | 3Ph + N + PE |
| Frekuensi input | 50 / 60 Hz, ±10% |
| Faktor daya input | ≥0,7 tanpa filter; ≥0,97 dengan filter |
| Teknologi penyearah | SCR |
| THDi input | <50% tanpa filter; <15% dengan filter |
Input bypass statis
| Rentang tegangan bypass | 176–264 V AC (Ph-N); 304–456 V AC (Ph-Ph) |
|---|---|
| Fase | 3Ph + N + PE |
| Rentang pelacakan frekuensi | 50 / 60 Hz, ±10% |
| Input generator | Didukung |
| Kemampuan beban berlebih bypass | 150–180%: 1 jam hingga 300 detik; >180%: 300 detik |
Output
| Kapasitas terukur | 10 kVA / 8 kW |
|---|---|
| Tegangan output nominal | 380 / 400 / 415 V AC, 3Ph + N |
| Regulasi tegangan output | ±1% |
| Faktor daya output | 0,8 |
| Frekuensi output – mode saluran | (50 / 60) ±0,01 Hz |
| Frekuensi output – mode baterai | (50 / 60) ±0,01 Hz |
| Bentuk gelombang output | Gelombang sinus |
| THDv – beban resistif | ≤2% |
| THDv – beban non-linear | ≤4% |
| Waktu transfer utilitas-ke-baterai | 0 ms |
| Efisiensi – mode saluran | 89% |
| Efisiensi – mode baterai | 90% |
Beban berlebih inverter
| ≤110% | 60 menit |
|---|---|
| ≤125% | 10 menit |
| ≤150% | 1 menit |
| >150% | 200 ms |
Penyearah, baterai, dan pengisi daya
| Tipe penyearah | 6-pulse |
|---|---|
| Tegangan DC terukur | 384 VDC |
| Tegangan pengisian daya | 395–435 VDC, dapat disesuaikan |
| Tipe baterai | Baterai asam timbal tersegel VRLA |
| Jumlah baterai | 32 pcs nominal; 29–32 dapat dikonfigurasi |
| Tegangan string baterai | 348 / 360 / 372 / 384 VDC |
| Arus pengisian daya | Hingga 40 A; 5 A pada beban UPS penuh (nilai yang tercantum produsen; arus yang tersedia bergantung pada beban operasi dan konfigurasi pengisi daya). |
Komunikasi dan manajemen
| Komunikasi | RS232, USB, RS485, kontak kering; 1 slot kartu komunikasi untuk kartu SNMP opsional |
|---|---|
| Tampilan | LCD 3,5 inci; layar sentuh warna penuh 7 inci opsional |
| Fungsi alarm | Beban berlebih output, kelainan utilitas, kesalahan UPS, tegangan baterai rendah, riwayat alarm |
| Perlindungan | Hubung singkat output, beban berlebih output, suhu berlebih, tegangan baterai rendah, tegangan output berlebih/kurang, kegagalan kipas, perlindungan lonjakan |
| Mode ECO | Didukung |
| EPO | Didukung |
| Power walk-in | Didukung* |
| Pengontrol sinkronisasi | Opsional* |
| Klasifikasi UPS | VFI-SS-111 |
| Unit paralel | 4 pcs |
Data lingkungan dan fisik
| Suhu operasi | 0–55°C |
|---|---|
| Suhu penyimpanan | -25–55°C, tidak termasuk baterai |
| Kelembaban relatif | <95%, non-kondensasi |
| Ketinggian operasi | 0–1500 m pada beban 100% |
| Kebisingan akustik | 70 dB pada beban 100% |
| Peringkat perlindungan | IP20 |
| Lapisan konformal | Didukung |
| Filter debu | Didukung |
| Dimensi | 405 × 656 × 817 mm (L × D × T) |
| Berat | 118 kg |
Standar yang dirujuk dalam spesifikasi produsen
| Persyaratan EMC UPS | IEC/EN 62040-2 |
|---|---|
| Metode uji kekebalan EMC | IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8 |
| Kinerja UPS | IEC 62040-3 |
| Referensi pasar Cina | GB/T 14715-2017; YD/T 1095-2018 |
Referensi ini muncul dalam spesifikasi produsen dan bukan, dengan sendirinya, bukti kepatuhan terhadap edisi standar tertentu. Harap minta laporan uji atau deklarasi yang relevan jika diperlukan.
*Fungsi yang ditandai dengan tanda bintang adalah opsi yang dapat dikonfigurasi sesuai dengan spesifikasi sumber. Spesifikasi dapat berubah.
Pertimbangan instalasi
Periksa urutan fase, koneksi netral, dan pentanahan pelindung terhadap gambar listrik. Identifikasi sirkuit hilir mana yang sebenarnya termasuk dalam beban cadangan 8 kW sebelum memilih pemutus AC dan rute kabel.
Bank baterai bersifat eksternal. Sediakan lokasi terpisah untuk itu, hitung arus pembuangan untuk periode cadangan yang diperlukan, dan jaga agar perlindungan DC dapat diakses untuk pemeliharaan.
Minta penawaran W-10KL
Untuk tinjauan konfigurasi, berikan beban terhubung Anda dalam kW atau kVA, tegangan input/output lokasi, waktu cadangan yang diperlukan, dan persyaratan motor start atau generator apa pun. Kami dapat meninjau susunan UPS dan baterai eksternal terhadap detail tersebut.
Minta PenawaranButuh kapasitas UPS lain?
Lihat seri UPS Frekuensi Rendah lengkap untuk kapasitas dan konfigurasi tiga fase lainnya.