W-160KL 160 kVA Low Frequency Online UPS with Isolation Transformer, 3-Phase 380 V Input/Output

Basic Properties
Place of Origin: China
Brand Name: BLAZING POWER
Certification: CE
Model Number: W-160KL
Trading Properties
Minimum Order Quantity: 1 Unit
Price: 9750USD
Standard Packaging: Pallet
Delivery Time: 3-5 Days
Payment Terms: T/T,Western Union,L/C
Supply Ability: Stock
Specifications
Capacity: 160 kVA / 128 kW Topology: Low frequency, online double-conversion
Input / Output: 380 / 400 / 415 V AC, 3-phase Input Voltage Range: 285–485 V AC
Input frequency range: 50 / 60 Hz, ±10% Isolation transformer: Built-in output isolation transformer
Transfer time: 0 ms (mains to battery) Battery system: 384 VDC nominal, 32 × 12 V batteries (29–32 adjustable)
High Light:

120 kVA low frequency UPS

,

3-phase 380V input UPS

,

3-phase 380V output UPS

Product Description

BLAZING POWER W-160KL offers 160 kVA / 128 kW for large three-phase equipment groups, imaging departments and industrial systems. It uses an output isolation transformer and separate main and bypass input circuits. Battery backup is provided by an external 384 VDC bank configured for the site's load and required duration.

Check the largest demand event first

At 160 kVA, selection often turns on a few high-demand events: a medical scanner cycle, a machine startup or multiple loads changing state together. The equipment supplier's electrical data and the plant load schedule take priority over a simple sum of nominal kVA figures.

The main input operates over 285–485 V AC line-to-line; static bypass is rated for 304–456 V AC line-to-line. Confirm the upstream arrangement against both ranges rather than assuming the bypass follows the rectifier window.

160 kVA / 128 kWRated three-phase output at an output power factor of 0.8.
380 / 400 / 415 V ACThree-phase input and output voltage options.
285–485 V ACMain input range, measured phase-to-phase (Ph-Ph).
384 VDCNominal external battery system using 32 × 12 V batteries.

160 kVA installation types

Medical imaging departments: CT and selected MRI-related loads after verifying the equipment maker’s supply, peak input and any special installation requirements.
Centralized manufacturing: Several production machines and automation cabinets sharing a UPS-backed distribution board.
Industrial process systems: Plant control, monitoring and electrical process loads that need a controlled response to grid failure.
Data and network facilities: Larger communications, storage and control-room loads with a documented continuity requirement.

If a project contains several imaging or industrial loads, include the operating schedule. Not every machine peaks at the same time, but assuming that none do can also lead to an undersized system.

Battery configuration

The W-160KL uses an external VRLA battery bank. The nominal system is 384 VDC with 32 × 12 V batteries. The battery quantity can be configured from 29 to 32 batteries, corresponding to 348 / 360 / 372 / 384 VDC.

Charging voltage is adjustable from 395–435 VDC. The manufacturer lists charging-current values of up to 40 A and 5 A at full UPS load. Available charging current depends on UPS loading and the supplied charger configuration. Battery Ah capacity should be selected based on the connected load and required backup time.

Technical specifications

View full technical specifications

Main input

Nominal input voltage 380 / 400 / 415 V AC
Input voltage range 165–280 V AC (Ph-N); 285–485 V AC (Ph-Ph)
Phase 3Ph + N + PE
Input frequency 50 / 60 Hz, ±10%
Input power factor ≥0.7 without filter; ≥0.97 with filter
Rectifier technology SCR
Input THDi <50% without filter; <15% with filter

Static bypass input

Bypass voltage range 176–264 V AC (Ph-N); 304–456 V AC (Ph-Ph)
Phase 3Ph + N + PE
Frequency tracking range 50 / 60 Hz, ±10%
Generator input Supported
Bypass overload capability 150–180%: 1 hour to 300 seconds; >180%: 300 seconds

Output

Rated capacity 160 kVA / 128 kW
Nominal output voltage 380 / 400 / 415 V AC, 3Ph + N
Output voltage regulation ±1%
Output power factor 0.8
Output frequency – line mode (50 / 60) ±0.01 Hz
Output frequency – battery mode (50 / 60) ±0.01 Hz
Output waveform Sine wave
THDv – resistive load ≤2%
THDv – nonlinear load ≤4%
Utility-to-battery transfer time 0 ms
Efficiency – line mode 91%
Efficiency – battery mode 92%

Inverter overload

≤110% 60 minutes
≤125% 10 minutes
≤150% 1 minute
>150% 200 ms

Rectifier, battery and charger

Rectifier type 6-pulse
Rated DC voltage 384 VDC
Charging voltage 395–435 VDC, adjustable
Battery type VRLA sealed lead-acid battery
Battery quantity 32 pcs nominal; 29–32 configurable
Battery string voltage 348 / 360 / 372 / 384 VDC
Charging current Up to 40 A; 5 A at full UPS load (manufacturer-listed values; available current depends on operating load and charger configuration).

Communication and management

Communication RS232, USB, RS485, dry contacts; 1 communication-card slot for optional SNMP card
Display 3.5-inch LCD; optional 7-inch full-color touchscreen
Alarm functions Output overload, utility abnormality, UPS fault, low battery voltage, alarm history
Protection Output short circuit, output overload, overtemperature, low battery voltage, output over/undervoltage, fan failure, surge protection
ECO mode Supported
EPO Supported
Power walk-in Supported*
Synchronization controller Optional*
UPS classification VFI-SS-111
Parallel units 4 pcs

Environment and physical data

Operating temperature 0–55°C
Storage temperature -25–55°C, excluding batteries
Relative humidity <95%, non-condensing
Operating altitude 0–1500 m at 100% load
Acoustic noise 70 dB at 100% load
Protection rating IP20
Conformal coating Supported
Dust filter Supported
Dimensions 705 x 1051 x 1646 mm (W × D × H)
Weight 760 kg

Standards referenced in the manufacturer specification

UPS EMC requirements IEC/EN 62040-2
EMC immunity test methods IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8
UPS performance IEC 62040-3
China market references GB/T 14715-2017; YD/T 1095-2018

These references appear in the manufacturer specification and are not, on their own, proof of conformity to a particular standard edition. Please request the relevant test reports or declarations where required.

*Functions marked with an asterisk are configurable options according to the source specification. Specifications are subject to change.

Installation considerations

Prepare separate calculations for upstream AC power, outgoing load circuits and the DC battery link. Battery discharge current and conductor sizing depend on actual load and cable length, not just UPS kVA.

Confirm lifting and service access for the 705 x 1051 x 1646 mm, 760 kg cabinet. Any generator or external maintenance bypass should be coordinated with the project's single-line diagram.

Request a W-160KL quotation

For sizing support, provide the protected-load schedule, simultaneous peak demand, site input/output voltage, required battery autonomy and generator or bypass arrangements. The UPS and battery system must be specified together.

Request a Quote