logo

Dual Input Low Frequency UPS 10KVA Pure Sinewave Output for Medical Devices

Basic Properties
Place of Origin: China
Brand Name: BLAZING POWER
Certification: CE
Model Number: W-20KL
Trading Properties
Minimum Order Quantity: 1 Unit
Price: 2000-5000$/Unit
Payment Terms: T/T,Western Union,L/C
Supply Ability: Stock
Specifications
Capcity: 10KVA/8KW Input: 3 X 380VAC/400VAC (3Ph + N)
Frequency: 50Hz&60Hz Nominal Battery Voltage: 384 VDC (Based On 32pcs Batteries)
Precision: Stationary: ±1% Transitory: ±5% (load Variations 100-0-100%) Waveform: Pure Sinewave
Output: 3 X 380VAC/400VAC (3Ph + N) Transfer Time: Zero
Current Limit: High Overload, Short-circuit: RMS Voltage Limit High Crest-Factor Current: Peak Voltage Limit Charging Current: Default 10A; Maximum 40A; 5A@ Full Load
Capcity: 20KVA/16KW Input: 3 X 380VAC/400VAC (3Ph + N)
Frequency: 50Hz&60Hz Nominal Battery Voltage: 384 VDC (Based On 32pcs Batteries)
Precision: Stationary: ±1% Transitory: ±5% (load Variations 100-0-100%) Waveform: Pure Sinewave
Output: 3 X 380VAC/400VAC /415VAC(3Ph + N) Transfer Time: Zero
Current Limit: High Overload, Short-circuit: RMS Voltage Limit High Crest-Factor Current: Peak Voltage Limit Charging Current: Default 10A;
High Light:

Low Frequency UPS 10KVA

,

Dual Input Low Frequency UPS

,

Medical Devices Uninterruptible Power Supply

Product Description
Dual-Input Line-Low Frequency UPS 20KVA
Medical Device Dedicated UPS

Designed specifically for medical applications, this UPS system ensures security and stability for critical healthcare equipment.

Security & Stability Features
  • Utilizes microprocessors for fully digital control of all UPS power conversion stages, enhancing system consistency and stability
  • Incorporates controllable rectifier design to significantly improve grid adaptability, ensuring greater safety and reliability for the inverter
  • Features a built-in output isolation transformer to minimize the impact of neutral-to-ground voltage and load harmonic currents on the inverter
  • Independent battery interfaces prevent critical failures caused by installation errors, substantially reducing operational risks
  • Over 90% of components utilize internationally renowned brands, with each unit undergoing 24-hour burn-in testing and validation before shipment
Product Features
  • Double-conversion online design delivers pure sine wave output, providing critical loads with stable voltage and frequency power supply free from grid disturbances
  • During mains failure, the UPS inverts battery energy to the load, ensuring uninterrupted power output
  • High-frequency double-conversion architecture with output isolation transformer and advanced fully digital control technology for stable, clean, and uninterrupted power
  • Diverse communication solutions including MODBUS, RS232, and expandable smart slot for convenient configuration and monitoring
System Architecture

Primary components include rectifier and inverter modules forming double-conversion circuit (AC to DC to AC), plus static bypass, maintenance bypass, and battery charge/discharge circuits. Mains power and bypass switching via thyristors in reverse parallel configuration acting as transfer switches.