W-200KL 200 kVA Low Frequency Online UPS with Isolation Transformer, 3-Phase 380 V Input/Output

Basic Properties
Place of Origin: China
Brand Name: BLAZING POWER
Certification: CE
Model Number: W-200KL
Trading Properties
Minimum Order Quantity: 1 Unit
Price: 10850$/Unit
Standard Packaging: Pallet
Delivery Time: 3-5 Days
Payment Terms: T/T,Western Union,L/C
Supply Ability: Stock
Specifications
Capacity: 200 kVA / 160 kW Topology: Low frequency, online double-conversion
Input / Output: 380 / 400 / 415 V AC, 3-phase Input Voltage Range: 285–485 V AC (Ph-Ph)
Input frequency range: 50 / 60 Hz, ±10% Isolation transformer: Built-in output isolation transformer
Transfer Time: 0 ms (mains to battery) Battery system: 384 VDC nominal, 32 × 12 V batteries (29–32 adjustable)
High Light:

Three Phase UPS Power Supply 200KVA

,

Three Phase UPS Power Supply 160KW

,

Pure Sinewave Output Uninterruptible Power Supply

Product Description

The W-200KL is the 200 kVA / 160 kW model in this three-phase low frequency UPS range. Its output isolation transformer and separate input paths make it suitable for projects with a substantial protected distribution. The UPS cabinet and external VRLA battery bank are specified as parts of one electrical system, not as interchangeable stand-alone items.

High-capacity power requires a system-level check

At this rating, the central question is which loads will remain connected during a utility failure and how they behave at peak demand. A plant may have several machines operating simultaneously; an imaging facility may include equipment with distinct input peaks and operating schedules.

The output is 200 kVA / 160 kW. Battery autonomy, input protection and generator compatibility have to be assessed separately. The 285–485 V AC main input range does not replace the separate 304–456 V AC static bypass specification.

200 kVA / 160 kWRated three-phase output at an output power factor of 0.8.
380 / 400 / 415 V ACThree-phase input and output voltage options.
285–485 V ACMain input range, measured phase-to-phase (Ph-Ph).
384 VDCNominal external battery system using 32 × 12 V batteries.

Projects that call for a 200 kVA UPS

Large imaging installations: CT or MRI facilities only after the equipment maker’s maximum input demand, peaks and special supply conditions are checked.
Plant-wide essential distribution: A defined set of production and control loads supplied from a protected three-phase switchboard.
Industrial process lines: High-capacity manufacturing or process equipment with calculated simultaneous maximum demand.
Data and control infrastructure: Centralized network, storage, automation and supervisory systems that have a specified backup objective.

Do not use 200 kVA as a proxy for a fixed number of machines or minutes of battery runtime. The protected-load schedule and requested autonomy determine the electrical and battery design.

Battery configuration

The W-200KL uses an external VRLA battery bank. The nominal system is 384 VDC with 32 × 12 V batteries. The battery quantity can be configured from 29 to 32 batteries, corresponding to 348 / 360 / 372 / 384 VDC.

Charging voltage is adjustable from 395–435 VDC. The manufacturer lists charging-current values of up to 40 A and 5 A at full UPS load. Available charging current depends on UPS loading and the supplied charger configuration. Battery Ah capacity should be selected based on the connected load and required backup time.

Technical specifications

View full technical specifications

Main input

Nominal input voltage 380 / 400 / 415 V AC
Input voltage range 165–280 V AC (Ph-N); 285–485 V AC (Ph-Ph)
Phase 3Ph + N + PE
Input frequency 50 / 60 Hz, ±10%
Input power factor ≥0.7 without filter; ≥0.97 with filter
Rectifier technology SCR
Input THDi <50% without filter; <15% with filter

Static bypass input

Bypass voltage range 176–264 V AC (Ph-N); 304–456 V AC (Ph-Ph)
Phase 3Ph + N + PE
Frequency tracking range 50 / 60 Hz, ±10%
Generator input Supported
Bypass overload capability 150–180%: 1 hour to 300 seconds; >180%: 300 seconds

Output

Rated capacity 200 kVA / 160 kW
Nominal output voltage 380 / 400 / 415 V AC, 3Ph + N
Output voltage regulation ±1%
Output power factor 0.8
Output frequency – line mode (50 / 60) ±0.01 Hz
Output frequency – battery mode (50 / 60) ±0.01 Hz
Output waveform Sine wave
THDv – resistive load ≤2%
THDv – nonlinear load ≤4%
Utility-to-battery transfer time 0 ms
Efficiency – line mode 91%
Efficiency – battery mode 92%

Inverter overload

≤110% 60 minutes
≤125% 10 minutes
≤150% 1 minute
>150% 200 ms

Rectifier, battery and charger

Rectifier type 6-pulse
Rated DC voltage 384 VDC
Charging voltage 395–435 VDC, adjustable
Battery type VRLA sealed lead-acid battery
Battery quantity 32 pcs nominal; 29–32 configurable
Battery string voltage 348 / 360 / 372 / 384 VDC
Charging current Up to 40 A; 5 A at full UPS load (manufacturer-listed values; available current depends on operating load and charger configuration).

Communication and management

Communication RS232, USB, RS485, dry contacts; 1 communication-card slot for optional SNMP card
Display 3.5-inch LCD; optional 7-inch full-color touchscreen
Alarm functions Output overload, utility abnormality, UPS fault, low battery voltage, alarm history
Protection Output short circuit, output overload, overtemperature, low battery voltage, output over/undervoltage, fan failure, surge protection
ECO mode Supported
EPO Supported
Power walk-in Supported*
Synchronization controller Optional*
UPS classification VFI-SS-111
Parallel units 4 pcs

Environment and physical data

Operating temperature 0–55°C
Storage temperature -25–55°C, excluding batteries
Relative humidity <95%, non-condensing
Operating altitude 0–1500 m at 100% load
Acoustic noise 70 dB at 100% load
Protection rating IP20
Conformal coating Supported
Dust filter Supported
Dimensions 705 × 1051 × 1646 mm (W × D × H)
Weight 790 kg

Standards referenced in the manufacturer specification

UPS EMC requirements IEC/EN 62040-2
EMC immunity test methods IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8
UPS performance IEC 62040-3
China market references GB/T 14715-2017; YD/T 1095-2018

These references appear in the manufacturer specification and are not, on their own, proof of conformity to a particular standard edition. Please request the relevant test reports or declarations where required.

*Functions marked with an asterisk are configurable options according to the source specification. Specifications are subject to change.

Installation considerations

Provide a current and cable schedule for the AC mains, bypass, output and DC battery circuits. Specify the external battery bank and its protection from the actual 160 kW maximum output and intended runtime.

At 705 × 1051 × 1646 mm and 790 kg, the cabinet needs a documented delivery path, floor-loading check and service clearance. Match the generator and upstream switchgear to the final design rather than to a nominal kVA rule.

Request a W-200KL quotation

For sizing support, provide the protected-load schedule, simultaneous peak demand, site input/output voltage, required battery autonomy and generator or bypass arrangements. The UPS and battery system must be specified together.

Request a Quote