Pure Sinewave UPS Uninterruptible Power Supply 60KVA 48KW for Medical Devices
Basic Properties
Place of Origin:
China
Brand Name:
BLAZING POWER
Certification:
CE
Model Number:
W-60KL
Trading Properties
Minimum Order Quantity:
1 Unit
Price:
3000-5000$/Unit
Payment Terms:
T/T,Western Union,L/C
Supply Ability:
Stock
Specifications
| Capcity: | 60KVA/48KW | Input: | 3 X 380VAC/400VAC (3Ph + N) |
| Frequency: | 50Hz&60Hz | Nominal Battery Voltage: | 384 VDC (Based On 32pcs Batteries) |
| Precision: | Stationary: ±1% Transitory: ±5% (load Variations 100-0-100%) | Waveform: | Pure Sinewave |
| Output: | 3 X 380VAC/400VAC (3Ph + N) | Transfer Time: | Zero |
| Current Limit: | High Overload, Short-circuit: RMS Voltage Limit High Crest-Factor Current: Peak Voltage Limit | Charging Current: | Default 10A; Maximum 40A; 5A@ Full Load |
| High Light: | UPS Uninterruptible Power Supply 60KVA,UPS Uninterruptible Power Supply 48KW,Medical Devices UPS Power Supply |
||
Product Description
Medical Device Dedicated UPS
Security & Stability
- Utilizes microprocessors for fully digital control of all UPS power conversion stages, enhancing system consistency and stability.
- Incorporates controllable rectifier design to significantly improve grid adaptability, ensuring greater safety and reliability for the inverter.
- Features a built-in output isolation transformer to minimize the impact of neutral-to-ground voltage and load harmonic currents on the inverter.
- Independent battery interfaces prevent critical failures caused by installation errors, substantially reducing operational risks.
- Over 90% of components utilize internationally renowned brands, with each unit undergoing 24-hour burn-in testing and validation before shipment.
Product Features
- Double-conversion online design delivers pure sine wave output, providing critical loads with stable voltage and frequency power supply free from grid disturbances.
- During mains failure, the UPS inverts battery energy to the load, ensuring uninterrupted power output.
- High-frequency double-conversion architecture with output isolation transformer and advanced fully digital control technology for stable, clean, and uninterrupted power
- Diverse communication solutions including MODBUS, RS232, and expandable smart slot for convenient configuration and monitoring
- Primary components include rectifier and inverter modules forming double-conversion circuit (AC to DC to AC), plus static bypass, maintenance bypass, and battery charge/discharge circuits
- Mains power and bypass switching via thyristors in reverse parallel configuration acting as transfer switches