UPS Online Frekuensi Rendah 10 kVA, Input 3-Fasa 380 V / Output 3-Fasa 380 V
| Capcity: | 10KVA/8KW | Input: | 3 x 380VAC/400VAC (3Ph + N) |
| Frequency: | 50Hz&60Hz | Nominal Battery Voltage: | 384 VDC (Based on 32pcs batteries) |
| Precision: | Stationary: ±1% Transitory: ±5% (load variations 100-0-100%) | Waveform: | Pure Sinewave |
| Output: | 3 x 380VAC/400VAC (3Ph + N) | Transfer Time: | Zero |
| Current Limit: | High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit | Charging Current: | Default 10A; Maximum 40A; 5A@ full load |
| Capacity: | 10 KVA / 8 KW | Topology: | Low Frequency, Online Double-conversion |
| Input Voltage: | 380 / 400 / 415 V AC | Rated output voltage options: | 380 / 400 / 415 V AC, 3Ph + N |
| Output waveform: | Sine Wave | Output Voltage Regulation: | ±1% |
| Transfer Time: | 0 Ms (mains To Battery) | Output Isolation Transformer: | Built-in |
| High Light: | UPS Frekuensi Rendah 10KVA,UPS Frekuensi Rendah Input Ganda,Perangkat Medis Pasokan Listrik Tanpa Gangguan |
||
UPS Online Frekuensi Rendah BLAZING POWER 10 kVA / 8 kW melindungi beban tiga fase yang memerlukan isolasi galvanis dan pasokan yang dapat bertahan jika terjadi kegagalan listrik. Diproduksi oleh Teknologi Shenzhen Tafeng, baterai ini menggabungkan konversi ganda online dengan transformator isolasi keluaran internal, dan mengambil daya siaga dari bank VRLA eksternal — 32 baterai pada nominal 384 V DC, dapat diatur dari 29 hingga 32 (348/360/372/384 V DC). Jumlah baterai yang dikonfigurasi menentukan voltase bank baterai nominal; runtime mengikuti kapasitas baterai yang ditentukan dan beban sebenarnya. Beban yang umum adalah kabinet kontrol PLC dan DCS, bangku laboratorium, panel manajemen gedung, dan sel produksi tunggal.
Kabinet ini berbobot 118 kg dan menempati luas lantai 405 × 656 mm — sama dengan peringkat 15 dan 20 kVA. Pemuatan lantai dan ukuran kabel bergantung pada peringkat yang sebenarnya dipasang dan dikonfirmasi per model. Arus keluaran terukur kira-kira 15,2 A per fase pada 380 V.
Input ganda, operasi paralel dan pemantauan
Input utama dan bypass yang terpisah mendukung instalasi sumber ganda, dengan koneksi generator pada bypass. Hingga empat unit dapat beroperasi secara paralel untuk kapasitas atau redundansi; pengontrol sinkronisasi adalah sebuah opsi. Antarmukanya adalah RS232, USB, RS485, dan kontak kering sebagai standar, dan slot komunikasi tunggal menggunakan kartu SNMP opsional di mana situs memerlukan pengawasan jaringan. Outputnya adalah gelombang sinus yang dipertahankan pada ±1%, dengan transfer 0 ms dari sumber listrik ke baterai.
Input utama menerima 285–485 V AC fase-ke-fase — cukup lebar untuk menahan beban melalui ayunan yang khas pada pengumpan pabrik dan genset. Jendela frekuensi input tercantum dalam tabel spesifikasi di bawah.
Penentuan ukuran dimulai dari daftar muatan, bukan katalog —bagaimana memilih UPS untuk rumah sakit, bank dan pabrikberjalan melalui urutan. Bank baterai berada di luar kabinet dan pengoperasian DC memiliki batas praktis:seberapa jauh jarak UPS dari lemari baterai.
Fitur Utama
Isolasi transformator
Arsitektur frekuensi rendah dengan transformator isolasi keluaran bawaan.
Masukan sumber ganda
Pisahkan input utama dan bypass, ditambah koneksi generator pada bypass.
Keluaran terus menerus
Transfer listrik ke baterai 0 ms, output gelombang sinus, regulasi tegangan ±1%.
Siap secara paralel
Hingga 4 unit secara paralel; pengontrol sinkronisasi tersedia sebagai opsi.
Pengaturan baterai yang fleksibel
Konfigurasi nominal 32 baterai pada 384 V DC; 29–32 baterai dapat dikonfigurasi.
Antarmuka pemantauan
RS232, USB, RS485 dan kontak kering; Kartu SNMP tersedia sebagai opsi.
Perlindungan & kontrol
Perlindungan hubung singkat, kelebihan beban, dan suhu berlebih, ditambah mode ECO dan EPO.
Aplikasi Khas
Kabinet kontrol PLC dan DCS
Satu kabinet kontrol dan apa saja yang menggantung — rak PLC dan DCS, panel HMI, catu daya 24 V, pemancar, katup solenoid. Bus ini berjalan melalui transformator isolasi keluaran, dan kegagalan listrik berpindah dalam 0 ms.
Manajemen gedung dan panel akses
Head-end BMS, pengontrol kontrol akses, pengukur energi, dan pengontrol pencahayaan berbagi satu papan tiga fase. Runtime diatur berdasarkan waktu pencadangan yang ditentukan situs dan berdasarkan beban yang benar-benar tersambung.
Bangku laboratorium dan peralatan bangku
Alat analisa bangku, inkubator, pengatur lemari asam dan pompa vakum kecil serta sentrifugal di bawah meja. Jika motor berbagi sirkuit, permintaan startnya diperiksa terhadap selubung inverter (≤110% selama 60 menit, ≤125% selama 10 menit, ≤150% selama 1 menit) daripada diasumsikan.
Sel produksi tunggal
Satu sel, bukan satu saluran: sirkuit kontrol mesin, instrumentasinya, stasiun penyortiran atau pelabelan, dan pompa bantu kecil di sampingnya. Apa pun yang lebih dari itu — penggerak utama, bank pemanas, atau seluruh mesin — merupakan penilaian per beban, bukan sesuatu yang ditentukan sendiri oleh peringkat.
Untuk sel produksi tunggal, aplikasi yang tercantum di sini mengacu pada beban kontrol dan tambahan. Pencadangan seluruh mesin memerlukan penilaian terpisah mengenai daya pengoperasian, arus dan durasi start, karakteristik penggerak, dan kemampuan beban berlebih UPS.
Spesifikasi Teknis
| Parameter | spesifikasi 10 kVA |
|---|---|
| Peringkat & arsitektur | |
| Kapasitas terukur | 10 kVA / 8kW |
| Model | W-10KL |
| Konfigurasi fase | Masukan 3 fase / keluaran 3 fase |
| Klasifikasi UPS | VFI-SS-111 |
| Masukan utama | |
| Tegangan terukur | 380/400/415 V AC, 3Ph + N + PE |
| Rentang tegangan | 285–485 V AC fase-ke-fase; 165–280 V AC fase ke netral |
| Rentang frekuensi | 50 ±5 Hz (±10%) / 60 ±6 Hz (±10%) |
| Lewati masukan | |
| Rentang tegangan | 304–456 V AC fase-ke-fase; 176–264 V AC fase ke netral |
| Koneksi pembangkit | Didukung |
| Keluaran & kinerja | |
| Tegangan keluaran terukur | 380/400/415 V AC, 3Ph + N |
| Pengaturan tegangan | ±1% |
| Faktor daya keluaran | 0,8 |
| Nilai arus keluaran | Sekitar 15,2 A per fase pada 380 V |
| Frekuensi, mode listrik/baterai | 50/60Hz ±0,01Hz |
| Bentuk gelombang | Gelombang sinus |
| Transfer listrik ke baterai | 0 ms |
| Efisiensi | mode garis 89%; Modus baterai 90%. |
| Kemampuan beban berlebih inverter | ≤110%: 60 menit; ≤125%: 10 menit; ≤150%: 1 menit; >150%: 200 mdtk |
| Melewati kemampuan kelebihan beban | 150–180%: dari 1 jam hingga 300 detik; >180%: 300 detik |
| Operasi paralel | |
| Unit maksimum secara paralel | 4 |
| Pengontrol sinkronisasi | Opsional |
| Baterai & pengisian daya | |
| Jenis baterai | VRLA menyegel asam timbal, bank eksternal |
| Sistem baterai nominal | 384 V DC, 32 baterai |
| Jumlah baterai yang dapat dikonfigurasi | 29–32; 348/360/372/384V DC |
| Kemampuan pengisian daya | Arus pengisian maksimum = min[daya terukur (kW) × 1000 / tegangan baterai (waktu nyata, V), 40 A] |
| Komunikasi & perlindungan | |
| Antarmuka standar | RS232, USB, RS485, kontak kering |
| Manajemen jaringan opsional | kartu SNMP; satu slot kartu komunikasi |
| Perlindungan | Hubungan pendek keluaran, kelebihan beban, suhu berlebih, tegangan baterai rendah, tegangan keluaran berlebih/kurang, kesalahan kipas, dan proteksi petir |
| Lingkungan, lingkungan & kepatuhan | |
| Suhu pengoperasian | 0–55 °C |
| Perlindungan masuknya | IP20 |
| Dimensi (L × D × T) | 405×656×817mm |
| Berat | 118kg |
| Standar | IEC/EN 62040-1-1 · IEC/EN 60950-1 · IEC 62040-3 · IEC/EN 62040-2 · IEC 62040-4 · CE |
Spesifikasi teknis tambahan
| Parameter | spesifikasi 10 kVA |
|---|---|
| Penyearah & kualitas masukan | |
| Penyearah | 6-pulsa, dikontrol thyristor |
| Faktor daya masukan | ≥0,7 tanpa filter; ≥0,97 dengan filter |
| Masukkan THDi saat ini | <50% tanpa filter; <15% dengan penyaring |
| Rentang pelacakan frekuensi, bypass | 50 ±5 Hz (±10%) / 60 ±6 Hz (±10%) |
| Detail keluaran | |
| Distorsi tegangan keluaran | ≤2% beban resistif; ≤4% beban nonlinier |
| Detail baterai & pengisian daya | |
| Tegangan bus DC | Nominalnya 384V DC |
| Tegangan pengisian | 395–435 V DC, dapat disesuaikan |
| Kemampuan pengisian daya | Arus pengisian maksimum = min[daya terukur (kW) × 1000 / tegangan baterai (waktu nyata, V), 40 A] |
| Standar pengisian baterai | DIN 41773 |
| Panel kontrol, alarm & fungsi | |
| Panel kontrol | LCD 3,5 inci; layar sentuh penuh warna opsional 7 inci |
| Alarm | Kelebihan beban keluaran, kelainan listrik, kesalahan UPS, tegangan baterai rendah; permintaan riwayat alarm |
| Fungsi lain yang didukung | modus ramah lingkungan; pemadaman darurat (EPO) |
| Lingkungan & mekanis | |
| Suhu penyimpanan | −25 hingga 55 °C, tidak termasuk baterai |
| Kelembaban relatif | <95%, tanpa kondensasi |
| Ketinggian operasi | 0–1.500 m pada beban 100%. |
| Kebisingan akustik | 70 dB pada beban 100%. |
| Lapisan konformal / penyaring debu | Didukung |
| Standar | |
| Keamanan | IEC/EN 62040-1-1, IEC/EN 60950-1 |
| Pertunjukan | IEC 62040-3 |
| EMC | IEC/EN 62040-2, IEC 61000-4-2, -4-3, -4-4, -4-5, -4-6, -4-8, EN 55022 |
| Persyaratan lingkungan | IEC 62040-4 |
| Menandai | CE |
Durasi pencadangan tergantung pada kapasitas baterai yang dipilih dan beban sebenarnya. Kapasitas baterai, waktu pengoperasian, dan kondisi lokasi dikonfirmasi berdasarkan pesanan.
Pertanyaan Umum
Berapa lama unit 10 kVA akan bekerja dengan baterai?
Durasi pencadangan diatur berdasarkan kapasitas baterai yang Anda tentukan dan beban sebenarnya, bukan berdasarkan rating UPS. Bank berada di luar kabinet, sehingga runtime tambahan sering kali dapat ditambahkan kemudian tanpa mengganti UPS — asalkan pengisi daya masih dapat mengisi ulang bank yang lebih besar dalam waktu yang tersedia dan rangkaian baru tersebut kompatibel dengan pengaturan baterai 29–32. Beri tahu kami daftar muatan dan menit yang Anda perlukan dan kami akan mengukur bank dan mengonfirmasi keduanya.
Bisakah jumlah baterai diubah dari 32?
Ya. Konfigurasi nominalnya adalah 32 baterai pada 384 V DC, dan unit dapat diatur untuk 29 hingga 32 baterai — 348, 360, 372 atau 384 V DC. Pengaturan jumlah baterai harus sesuai dengan rangkaian baterai sebenarnya. Waktu pencadangan tergantung pada konfigurasi baterai lengkap, kapasitas baterai, dan beban aktual. Arus pengisian daya mengikuti logika kontrol pengisi daya dan bank baterai benar-benar terhubung, dan tetap di bawah 40 A — ini adalah batas tertinggi, bukan nilai yang dicapai setiap pemasangan.
Bisakah dua unit 10 kVA diparalelkan?
Hingga empat unit dapat berjalan secara paralel, dan pengontrol sinkronisasi merupakan pilihan daripada perlengkapan standar. Pengoperasian paralel menambah kapasitas atau membeli redundansi, dan redundansi bersifat kondisional: unit yang dibiarkan online harus membawa seluruh beban, dan mengeluarkan satu untuk diservis memerlukan pengaturan bypass isolasi dan pemeliharaan yang disepakati saat papan dirancang. Katakan yang mana di antara keduanya yang Anda perlukan saat bertanya.
-
GThe packaging is secure; it’s a brand-new, unopened, factory-sealed unit. It’s easy to operate, and the data on the monitor is clear. I’m very satisfied.
-
DAs a medical equipment supplier, we purchased 20 sets of 120KVA industrial UPS to support hospital CT equipment operation. The UPS features stable voltage output, strong anti-interference and reliable performance, fully meeting medical power supply standards. Highly recommend BLAZING POWER professional UPS factory.
-