W-20KL 20 kVA Low Frequency Online UPS with Isolation Transformer, 3-Phase 380 V Input/Output

Basic Properties
Place of Origin: China
Brand Name: BLAZING POWER
Certification: CE
Model Number: W-20KL
Trading Properties
Minimum Order Quantity: 1 Unit
Price: 1200$/Unit
Standard Packaging: Pallet
Delivery Time: 3-5 Days
Payment Terms: T/T,Western Union,L/C
Supply Ability: Stock
Specifications
Capacity: 20 kVA / 16 kW Topology: Low Frequency, Online Double-conversion
Input / Output: 380 / 400 / 415 V AC, 3-phase Input Voltage Range: 285–485 V AC (Ph-Ph)
Input frequency range: 50 / 60 Hz, ±10% Isolation transformer: Built-in output isolation transformer
Transfer Time: 0 ms (mains to battery) Battery system: 384 VDC nominal, 32 × 12 V batteries (29–32 adjustable)
High Light:

8KW Low Frequency UPS

,

Self Adaptive Uninterruptible Power Supply

,

10KVA Low Frequency UPS

Product Description

BLAZING POWER W-20KL is rated 20 kVA / 16 kW, with three-phase input and output and a built-in output isolation transformer. It is a candidate for production support equipment and centralized control loads that need UPS-backed operation. The battery set is external, so the required autonomy is agreed during system design.

A 16 kW limit for real project loads

Production equipment rarely draws the same power throughout a cycle. Before specifying this UPS, compare normal running kW with startup and other short peaks; determine which equipment will run on battery and which can be shed.

The UPS accepts 380, 400 or 415 V nominal three-phase supply. Main and bypass voltages must both be checked because their permitted input ranges are not identical.

20 kVA / 16 kWRated three-phase output at an output power factor of 0.8.
380 / 400 / 415 V ACThree-phase input and output voltage options.
285–485 V ACMain input range, measured phase-to-phase (Ph-Ph).
384 VDCNominal external battery system using 32 × 12 V batteries.

Loads commonly considered for the W-20KL

Machine control and PLC systems: Control cabinets, production-line sensors and communication hardware that need time to shut down safely.
Light manufacturing cells: Selected tools, measuring systems and automation components after their maximum input demand is established.
Industrial test equipment: Three-phase benches, quality-control systems and test instrumentation requiring continuity through a mains interruption.
Remote operations: Monitoring and communications at water-treatment or utility-support sites with a suitably sized protected load.

For a production cell, write the backup load schedule first. It prevents the UPS quotation from accidentally including nonessential heating, compressors or other high-inrush equipment.

Battery configuration

The W-20KL uses an external VRLA battery bank. The nominal system is 384 VDC with 32 × 12 V batteries. The battery quantity can be configured from 29 to 32 batteries, corresponding to 348 / 360 / 372 / 384 VDC.

Charging voltage is adjustable from 395–435 VDC. The manufacturer lists charging-current values of up to 40 A and 5 A at full UPS load. Available charging current depends on UPS loading and the supplied charger configuration. Battery Ah capacity should be selected based on the connected load and required backup time.

Technical specifications

View full technical specifications

Main input

Nominal input voltage 380 / 400 / 415 V AC
Input voltage range 165–280 V AC (Ph-N); 285–485 V AC (Ph-Ph)
Phase 3Ph + N + PE
Input frequency 50 / 60 Hz, ±10%
Input power factor ≥0.7 without filter; ≥0.97 with filter
Rectifier technology SCR
Input THDi <50% without filter; <15% with filter

Static bypass input

Bypass voltage range 176–264 V AC (Ph-N); 304–456 V AC (Ph-Ph)
Phase 3Ph + N + PE
Frequency tracking range 50 / 60 Hz, ±10%
Generator input Supported
Bypass overload capability 150–180%: 1 hour to 300 seconds; >180%: 300 seconds

Output

Rated capacity 20 kVA / 16 kW
Nominal output voltage 380 / 400 / 415 V AC, 3Ph + N
Output voltage regulation ±1%
Output power factor 0.8
Output frequency – line mode (50 / 60) ±0.01 Hz
Output frequency – battery mode (50 / 60) ±0.01 Hz
Output waveform Sine wave
THDv – resistive load ≤2%
THDv – nonlinear load ≤4%
Utility-to-battery transfer time 0 ms
Efficiency – line mode 89%
Efficiency – battery mode 90%

Inverter overload

≤110% 60 minutes
≤125% 10 minutes
≤150% 1 minute
>150% 200 ms

Rectifier, battery and charger

Rectifier type 6-pulse
Rated DC voltage 384 VDC
Charging voltage 395–435 VDC, adjustable
Battery type VRLA sealed lead-acid battery
Battery quantity 32 pcs nominal; 29–32 configurable
Battery string voltage 348 / 360 / 372 / 384 VDC
Charging current Up to 40 A; 5 A at full UPS load (manufacturer-listed values; available current depends on operating load and charger configuration).

Communication and management

Communication RS232, USB, RS485, dry contacts; 1 communication-card slot for optional SNMP card
Display 3.5-inch LCD; optional 7-inch full-color touchscreen
Alarm functions Output overload, utility abnormality, UPS fault, low battery voltage, alarm history
Protection Output short circuit, output overload, overtemperature, low battery voltage, output over/undervoltage, fan failure, surge protection
ECO mode Supported
EPO Supported
Power walk-in Supported*
Synchronization controller Optional*
UPS classification VFI-SS-111
Parallel units 4 pcs

Environment and physical data

Operating temperature 0–55°C
Storage temperature -25–55°C, excluding batteries
Relative humidity <95%, non-condensing
Operating altitude 0–1500 m at 100% load
Acoustic noise 70 dB at 100% load
Protection rating IP20
Conformal coating Supported
Dust filter Supported
Dimensions 405 × 656 × 817 mm (W × D × H)
Weight 145 kg

Standards referenced in the manufacturer specification

UPS EMC requirements IEC/EN 62040-2
EMC immunity test methods IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8
UPS performance IEC 62040-3
China market references GB/T 14715-2017; YD/T 1095-2018

These references appear in the manufacturer specification and are not, on their own, proof of conformity to a particular standard edition. Please request the relevant test reports or declarations where required.

*Functions marked with an asterisk are configurable options according to the source specification. Specifications are subject to change.

Installation considerations

The 20 kVA cabinet is specified at 145 kg, without the external battery installation. Allow for moving and servicing the cabinet, and plan a separate protected DC route to the batteries.

Coordinate the input and bypass breakers with the upstream panels. Check the site's measured minimum voltage and the proposed generator supply, if present, before commissioning.

Request a W-20KL quotation

For a configuration review, send the combined running load in kW or kVA, site input/output voltage, required backup time and any motor starting or generator requirements. We can review the UPS and external battery arrangement against those details.

Request a Quote

Need another UPS capacity?

See the complete Low Frequency UPS series for other three-phase capacities and configurations.